SolarRiver 1100TL~1600TL Inverter Backboard
SolarRiver 2300TL~5200TL Inverter Backboard
Warning
Ensure that the DC side is not charged before installation or maintenance. If the
inverter is powered the capacitors will be charged if after the inverter is turned off,
hence it is to wait for 5 minutes to ensure that the capacitors are discharged.
Note
Inverters must be installed by qualified personnel only .
6.2 Pre installation precautions
Check the location where inverter is to be installed to ensure the following.
The ambient temperature is within the operation range ( -20°C to +60°C -4°F to +140°F ).
The altitude is less than 2,000 m.
Not prone to be damaged by sea water.
Not close to corrosive gas or liquid (for example, locations where chemicals are processed or lots of
poultry is fed).
Not exposed to direct sunlight.
Not prone to be flooded snowed in.
Ensure good ventilation and low humidity.
Not exposed to steam, vapor, or water.
160mm 160mm
60mm 60mm
167.5mm192mm
120mm130mm
104.5mm 104.5mm
25.5mm 25.5mm
85mm85mm
126.6mm