Résumé du contenu

Page 1 - SAMIL POWER

SAMIL POWERExpert for PV Grid-tied InvertersTMSP-SR-D-V1.1-ENSolarRiver-D PV Grid-tied InverterProduct ManualEnglishSolarRRiiver-DD PPVV GGriidd-ttiie

Page 2

3.2 Electrical block diagramElectrical block diagram of SolarRiver-D series inverter is as figure2. 3.3 Principle description Principle descri

Page 3 - Copyright Declaration

3.4 Protection function【More equipment protection】 SolarRiver-D series can run safely in any working condition because of the following protection

Page 4

10Introduction of SolarRiver-D series inverter & Operation Mode 3.7 Product labelThe product label provides basic information of the inverter,

Page 5 - CONTENTS

5 Installation 5.1 Installation process● Ready to install(refer to 5.2、5.3、5.4、5.5) Complete the preparation before installation: √ Read

Page 6

12InstallationType Project No. Description QTY Remark Equipment 1 PV Grid-tied Inverter 1 unitAccessories 2 Bracket1 pc 3 Installation Kit 1set 4 ca

Page 7 - 1 Notes on This Manual

Installation13● The ambient temperature is out the range of -20°C to +60°C ● The altitude 2,000 m above sea level. ● Prone to be damaged by water.● Cl

Page 8 - Warning!

Installation145.5 Installation tools5.6 Installation stepsBelow tools are needed before installation.Step1: Drill holes in the wall with diamete

Page 9 - 3.1 New featuresity

Installation15Step2:Put the inverter onto the bracket.Step 3: Use M5 hex key nut to fix the bottom of the inverter.Step4: Lock the inverter and the br

Page 10 - RS485/WiFi/GPRS

16Installation5.7 Connections of the PV power system5.7.1 Announcements5.7.2 PV array connection typesEnsure that the DC side is not charged before

Page 11 - 3.6 Dimension

InstallationPlease use PV cable to connect arrays to inverter. From junction box to inverter, voltage drop is about 1-2%. So we suggest the inverter b

Page 13 - 5 Installation

Installation5.7.4 Assembly steps of AC connectorSolarRiver series inverters are designed for single phase grid. Technical data should comply with the

Page 14 - 5.4 Installation precaution

InstallationThis product is equipped with IP66 AC connector. You can connect inverter AC side by yourself. Please see figure 15 for AC connector disas

Page 15 - Normal Fault

InstallationStep4: Screw down the threaded sleeve.Step5: Screw down the pressure screw.Step6: Connect AC connector to inverter.5.7.5 GroundingNeither

Page 16 - 5.6 Installation steps

Run the inverter6 Run the inverter6.1 Safety inspectionPV arrayInspect the PV array to determine whether each PV array opening voltage meets the st

Page 17 - Installation

Run the inverter22Step1: language settingMove the cursor to select language, press "OK" to select and press "OK" to confirm.Note:

Page 18 - Table 2 DC Voltage Limitation

Run the inverterStep4:Check settings informationLCD will display the settings information. Please check the settings information. If setting is wrong,

Page 19

Operation247 Operation7.1 Control and Display PanelControl and Display Panel of SolarRiver inverter is shown as figure 18.Figure 18 HMI InterfaceTher

Page 20

Operation257.2 Interface setting7.2.1 home interfaceEnter home interface automatically after startup (If not the home interface, press “ESC” return t

Page 21 - Pressure screw

Operation267.2.5 Event listMove the cursor to the" Event List" and then press “OK”, the user will see the list of events of inverter. Record

Page 22 - 5.7.5 Grounding

Communication and Monitoring278 Communication and Monitoring8.1 Communication InterfaceStandard configuration:1. Ethernet: Transmit the inverter wo

Page 23 - 6 Run the inverter

Copyright DeclarationThe copyright of this manual belongs to Samil Power Co., Ltd. Any corporation or individual should not plagiarize, partially copy

Page 24 - Language

Communication and Monitoring28Parameter setting when using router: Step 1:Enter home interface automatically after startup (If not the home interface

Page 25 - End commission

Communication and Monitoring29Step 4: Move the cursor to "network", press "OK" and then enter "Input Password" interface

Page 26 - 7.1 Control and Display Panel

30Communication and MonitoringPress "OK" twice then will enter "Manual-IP" interface. Press "right" or "left"

Page 27 - 7.2 Interface setting

Communication and Monitoring318.2.2 RS485 CommunicationRS485 is generally for at most 32 inverters communication at the same time. But the length of c

Page 28 - 7.2.6 Settings

Communication and Monitoring32The communication cable between inverter and Solar-Log:1. One side of cable is the same as cable between inverter and i

Page 29 - 8.2 Communication mode

Communication and Monitoring33WIFI settings:Note:Appendix is WIFI route list.Step1: Connect a cable following the steps of Ethernet before opening &qu

Page 30 - Settings

34Communication and MonitoringThe GUI bellow tells the WIFI hasn’t been set yet.If WIFI has been set, shown as following figure.Hardware Requirements:

Page 31 - Ethernet

Communication and Monitoring35Step3: Double-click name of inverter then enter detail information interface. Set the PIN code, service center number an

Page 32 - Left/Right : Move Selection

Communication and Monitoring & Troubleshooting and maintenance36If GPRS setting has been initialised, press "OK" to check the informatio

Page 33 - G/ GB/ Br/BrO/ O B

Troubleshooting and maintenance37-Wait grid go back to normal working state.-Mak sure that grid voltage and frequency complies with standards.-Or, pl

Page 35

38 Troubleshooting and maintenance & Decommissioning9.2 Daily maintenanceInverters generally do not need any maintenance or calibration, but ens

Page 37 - GPRS Message

40Technical Data & Guarantees11.4 General data12 Guarantees Samil Power Co., Ltd offers 5 years warranty service for SolarRiver-D inver

Page 44

CONTENTS4 Operation Mode ... 10 031.1 Sc

Page 45

0410.1 Decommissioning steps ...10.2 Package ...

Page 46

Notes on This Manual1 Notes on This Manual 1.1 Scope of ValidityThis manual is an integral part of the inverter. Please read the product manual ca

Page 47

Notes on This Manual 1.6 Important Safety InstructionsWhen using the product, please remember the below information to avoid the fire, lightning or

Page 48

2 Grid-tied System brief introduction 3.1 New featuresity3 Introduction of SolarRiver-D series inverterIn order to meet users the needs bette